International standards
Sphere radius, background light and vision target brightness, size, etc. of the projection perimeter in compliant perimeter in compliant witGoldmann standards.
- Color perimetry: a more sensitive detection of early visual fields defects
Accurate, fast Vision Testing
Eye position monitoring and automatic correction system (AEC), making sure the patient eye position correct
- Original intelligent testing strategies (IDT) : 3 minutes to complete a full inspection threshold
In addition to the standard Dynamic perimetry program (Standard 45, the standard 30, a high-resolution 15), users can also manually set the detection test perimeters, and ave it as usual Kinetic perimetry program
Comprehensive and versatile single analysis and reporting reliability: Accurate interpretation of perimetry results
- Reliability index : fixation loss, false-positive, automatic pupil measurement and staring cure.
- Report analysis : the overall bias decibel chart, the overall deviation probability plots, deviation decibel chart patterns, pattern deviation probability maps, average deviation, graphics deviation, GPA (Glaucoma Progress Analysis)
- Perimeter index : average deviation, graphice deviation, GHT hlf glaucoma vision alaysis, Vision Index (VFI)
- Dedicated projection perimetry software system
See the Link Video : https://drive.google.com/file/d/1qAdfGqpjmA4-aNdGBL66k2s3JmMTvp8x/view?usp=sharing
Technical Specification :
Model
|
APS – T00
|
Appearance
|
Intergrated Type
|
Stimulating Way
|
Optical projection
|
Projection Surface
|
Aspheric projection are
|
Detection Method
|
Dynamic perimetry
|
Detection scope
|
0 – 90º
|
Brightness Level
|
0 – 51 db
|
Testing Distance
|
300 mm
|
Visual Target Color
|
Red, Blue, White
|
Visual Target Brightness
|
0 asb – 10000 asb
|
Background Light
|
White(31.5asb), yellow(315asb)
|
Vision Target Interval time, keeping time
|
Patients adaptive, standard, slow, custom
|
Pupil Size Measurement
|
Auto
|
Head Movement Way
|
AEC Eye position monitoring and automatic correction system
|
Brightness Measurement
|
Brighness Auto Measurement and Correction
|
Visual Target Size (Goldmann standard)
|
I Grade, II Grade, III Grade IV Grade, V Grade
|
Detection strategy
|
Full-threshold, fast threshold, custom, Two notation, three notation, quantify defects, Intelligent dynamic, fast intelligent dynamic
|
Threshold policy
|
Age-related, threshold-related, single strength
|
Dynamic perimetry
|
Dynaic Program
|
Manual procedures, standard procedures (Standard 45, standard 30, high-resolution 15), Static point map, dark spot map, custom dynamic program
|
Stimulation Parameters
|
Adjustable (speed 1 – 9 / S, visual target size, color, intensity, test ranges, etc)
|
Fixation Monitoring
|
Dynamic real-time video monitoring, physiologist blind spot monitoring, Eye tracking curve, eye position offset alarm
|
Analysis Software
|
Reliability analysis, single vision analysis, triple report anaylzes, Overview vision analysis,
GHT glaucoma semi vision analysis, GPA glaucoma developing analysis
|
Report Figure
|
Value map, grayscale map, the overall bias decibel chart,
The overall deviation probability map, chart pattern deviation decibels,
Pattern deviation probability plot, staring Figure
|